• Dixell Refrigeration Controller Xc420c Two Compressor Parallel Controllers
  • Dixell Refrigeration Controller Xc420c Two Compressor Parallel Controllers
  • Dixell Refrigeration Controller Xc420c Two Compressor Parallel Controllers

Dixell Refrigeration Controller Xc420c Two Compressor Parallel Controllers

Installation Type: Tee Type
Sensing Type: Resistive
Contact: Contactless
Output Signal Type: Digital Type
Production Process: Injection
Material: Plastic
Customization:
Diamond Member Since 2011

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company, Other

Basic Info.

Model NO.
XC420C
Measuring Medium
Temperature
IP Rating
IP65
Certification
UL
Customized
Non-Customized
Type
Temperature Controller
Usage
Refrigerator
Control Type
Digital
Display Type
LED
Transport Package
Origional Packing
Specification
CE SGS
Trademark
Dixell
Origin
Italy
HS Code
8414301000
Production Capacity
50000PCS/Year

Product Description

Dixell Refrigeration Controller Two compressor parallel controllers XC420C
 

The XC420C is used to control the compressor or fan in the condenser system.

Compressor can be single stage, multi-level or different power.

The pressure or temperature of the LP side of the LP (compressor) or HP side (condenser side) is adjusted to cause the unit pressure

The force or temperature is controlled in a neutral or linear proportional region.

The unique internal programming algorithm can balance the operation time of each compressor and ensure the operation time of each compressor

Between homogeneous.

The controller can convert pressure and temperature display to each other.

The front control panel provides the full operating status of the system: the suction/condensation pressure (temperature) value, the load operation condition, whether it is in

Alarm or check status.

Each load has a corresponding alarm input.Once the alarm is activated, the controller will issue a protective action command to cut off the load in time.

Hot keys can be used to set the parameters quickly when starting up.

Through modbus-rtu protocol, TTL output ports can be provided with centralized monitoring system XWBE300D, XWED500 connection.

 
HOW TO ORDER
PRIME CX
X R - - C X - A B C D E
 
A B C D E
Power Supply Inputs - Buzzer X-REP
(excludes TTL output)
RS485  output -  Measurement       unit RTC - Compressor  output Connection
0 = 12Vac/dc P = PTC 0 No No No C °C No 0 8A Screw
= 12Vac/dc N = NTC 1 Yes No No F °F No 1 20A Screw
2 = 24Vdc S =Pt1000
  only for XR35/75CX
2 No Yes No H
 
°C 
heating only for   XR10CX
No 3 16A Screw
3 = 9 ÷40Vdc 3 Yes Yes No 6 8A Faston
4 = 110Vac -
-
-
-
4 No No Yes L °F 
heating only for   XR10CX
No 7 20A Faston
5 = 230Vac 5 Yes No Yes 8 16A Faston
-
-
6 No Yes Yes I °C Yes -
-
-
-
-
-
7 Yes Yes Yes M °F Yes

 


Dixell Refrigeration Controller Xc420c Two Compressor Parallel Controllers




Dixell Refrigeration Controller Xc420c Two Compressor Parallel Controllers
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.