Customization: | Available |
---|---|
After-sales Service: | 1 Year Warranty |
Warranty: | 1 Year Warranty |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
HERMETIC CONDENSING UNITRANGE OF APPLICATION
1.refrigeration industry,cold room project
2.Agriculture,food, restaurant,chemical industry
3.We offer customized design and services
The Condensing Units are prefabricated, monoblock type, factory tested and easy to mount on Cold Room's wall. The built-in electronic control panel with the microprocessor allows for manual setting of the desired temperature. It has the following components:
*An On-Off button for switching the unit on and off
*An On-Off Lighting button
*Three buttons for Temperature Setting
*A Manual Defrosting button
*A Digital Display showing the current room temperature.
All Condensing Units can be equipped with different kinds of refrigerants according to the clients'
model | nominal | refrigerating | specifications of connecting tube | dimension(mm) | installation size(mm) | |||||
HP | w | return gas(mm) | outlet(mm) | A | B | C | a | b | ||
MT28/FH22H | 2.5 | 4700 | 12 | 10 | 870 | 650 | 570 | 820 | 420 | |
MT36/FH33H | 3 | 6010 | 16 | 10 | 920 | 700 | 570 | 880 | 470 | |
MT50/FH37.5H | 4 | 7400 | 22 | 12 | 920 | 700 | 570 | 880 | 470 | |
MT64/FH49H | 5 | 9780 | 22 | 12 | 1020 | 700 | 670 | 980 | 460 | |
MT80/FH70H | 6.7 | 12380 | 28 | 16 | 1220 | 850 | 1080 | 1180 | 610 | |
MT100/FH80H | 8 | 14340 | 28 | 16 | 1220 | 850 | 1080 | 1180 | 610 | |
MT125/FH100H | 10 | 19190 | 28 | 16 | 1440 | 850 | 1280 | 1400 | 610 | |
MT160/FH130H | 13 | 24090 | 28 | 16 | 1220 | 850 | 1080 | 1180 | 610 | |
MT28/FH18M | 2.5 | 2730 | 12 | 10 | 640 | 545 | 520 | 590 | 315 | |
MT36/FH22M | 3 | 3560 | 16 | 10 | 870 | 650 | 570 | 820 | 420 | |
MT50/FH33M | 4 | 4280 | 22 | 12 | 920 | 700 | 570 | 880 | 470 | |
MT64/FH42M | 5 | 5690 | 22 | 12 | 1020 | 700 | 670 | 980 | 460 | |
MT80/FH55M | 6.7 | 7330 | 28 | 16 | 1220 | 850 | 770 | 1180 | 610 | |
MT100/FH70M | 8 | 8210 | 28 | 16 | 1220 | 850 | 1080 | 1180 | 610 | |
MT125/FH80M | 10 | 11450 | 28 | 16 | 1440 | 850 | 1280 | 1400 | 610 | |
MT160/FH115M | 13 | 14460 | 28 | 16 | 1440 | 850 | 1280 | 1400 | 680 | |
model | nominal | refrigerating | specifications of connecting tube | cooling water consumption m3/h | dimension(mm) | installation size(mm) | ||||
HP | w | return gas(mm) | outlet(mm) | A | B | C | a | b | ||
MT36/WN03M | 3 | 4330 | 16 | 10 | 1.3 | 810 | 300 | 600 | 600 | 250 |
MT50/WN05M | 4 | 5210 | 22 | 12 | 1.6 | 1010 | 350 | 720 | 780 | 300 |
MT64/WN05M | 5 | 6740 | 22 | 12 | 2 | 1010 | 350 | 720 | 850 | 300 |
MT80/WN08M | 6.7 | 8580 | 28 | 16 | 2.6 | 1080 | 350 | 720 | 890 | 300 |
MT100/WN10M | 8 | 10210 | 28 | 16 | 3.2 | 1120 | 350 | 800 | 890 | 300 |
MT125/WN10M | 10 | 13710 | 28 | 16 | 4 | 1120 | 350 | 800 | 990 | 300 |
MT160/WN15M | 13 | 17300 | 28 | 16 | 5.2 | 1220 | 400 | 800 | 780 | 350 |
MT36/WN05H | 3 | 6980 | 16 | 10 | 1.4 | 1010 | 350 | 720 | 780 | 300 |
MT40/WN05H | 3.5 | 7570 | 22 | 12 | 1.6 | 1010 | 350 | 720 | 780 | 300 |
MT50/WN06H | 4 | 8680 | 22 | 12 | 2 | 1010 | 350 | 720 | 850 | 300 |
MT64/WN08H | 5 | 11320 | 22 | 12 | 2.6 | 1080 | 350 | 720 | 890 | 300 |
MT80/WN10H | 6.7 | 14250 | 28 | 16 | 3 | 1120 | 350 | 800 | 890 | 300 |
MT100/WN10H | 8 | 17120 | 28 | 16 | 3.2 | 1120 | 350 | 800 | 890 | 300 |
MT125/WN15H | 10 | 22510 | 28 | 16 | 4.9 | 1220 | 400 | 800 | 990 | 350 |
MT160/WN15H | 13 | 28250 | 28 | 16 | 5.2 | 1220 | 400 | 800 | 990 | 350 |