• Dixell Refrigeration Prime Cx Digital Temperature Controller Air Cooled Type Tri-Output Thermostat Xr06cx-5n0c1
  • Dixell Refrigeration Prime Cx Digital Temperature Controller Air Cooled Type Tri-Output Thermostat Xr06cx-5n0c1

Dixell Refrigeration Prime Cx Digital Temperature Controller Air Cooled Type Tri-Output Thermostat Xr06cx-5n0c1

Customized: Non-Customized
Certification: CE
Brand: Dixell
Display Type: LED
Usage: Refrigerator
Control Type: Digital
Customization:
Diamond Member Since 2011

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company, Other

Basic Info.

Model NO.
Xr06cx-5N0C1
Type
Temperature Controller
Material
Plastic
Transport Package
Carton Box
Specification
CE SGS
Trademark
Dixell
Origin
Italy
HS Code
8414301000
Production Capacity
5000PCS/Year

Product Description

Dixell air cooled type tri-output thermostat  

Model:Xr06cx-5N0C1


 
The new PRIME series in CX format, is an innovative range of products that Dixell has introduced to the market for both heating and L.T., N.T. refrigeration. The CX family (32x74mm) has new functions plus an innovative and attractive design. The revolutionary introduction of 6 keys allows the user direct access to all main functions rapidly and intuitively, while the display with illuminated icons allows an instant view of the machine's status. All the instruments in CX format incorporate the latest know how and technology, both in software and hardware to ensure the highest standards of performance. 

Easy and intuitive installation
9 - 40Vdc power supply for refrigerated trucks (for models with 8A compressor)
Energy saving cycles triggered via a digital input; for example, it is possible to work at a set point that is different from the normal one in order to, for instance, accumulate cold when electric power is cheaper
Continuous cycle with dedicated set; it allows the machine to work during rapid cooling cycles to achieve the right product temperature
Regulation stop by auxiliary probe (beer dispenser applications); it is possible to supervise the tube temperature, stopping the compressor when the temperature becomes too low, and restarting when the correct values have been restored
Regulation re-start with door switch alarm
Max and Min temperature or HACCP function
Digital input configurable as probe
Virtual probe for air on / air off application; used in multideck applications where it is important to regulate temperature using the average of 2 temperatures
Dual thermostat function; is available, on demand, in applications such as white or red wine rooms where it is necessary to maintain 2 different temperatures
Condenser temperature management to prevent critical situations in the system
TTL serial connection for monitoring systems (using XJ485CX)
Connection for remote display X-REP (excludes TTL)
 

Thermostat and Controllers with  " OFF CYCLE"  DEFROST  for Normal, Medium  and  Low Temperature
 
 

XR10CX  
Thermostat with heating or cooling action.
XR20CX  Controller for NT with "off cycle" defrost.
XR30CX  Controller for NT with "off cycle" defrost and additional configurable relay.
XR35CX  Controller for NT with "off cycle" defrost and additional configurable relay and RS485.
XR36CX  2 set point controller for NT with "off cycle" defrost; created for applications where is necessary to maintain 
2 different temperature such as white/red wine rooms

 
         
Controllers  for  Normal, Medium  and  Low Temperature
 
 

XR40CX
Digital controller for MT  and LT with electrical or hot gas  defrost.
XR50CX   Controller for MT  and LT with electrical or hot gas  defrost and auxiliary relay.
XR56CX 2 set point controller for MT and LT with electrical or hot gas defrost and auxiliary relay; created for applications where is necessary to maintain 2 different temperature such as white/red wine rooms

 

Controllers  for Medium  and  Low Temperature
 

XR60CX 

Controller for MT and LT ventilated applications with dual humidity function on demand, this allows the user to activate or deactivate ventilation directly through keys, in order to regulate the humidity depending on the kind of product (ideal for pastry applications)

XR64CX   
Controller for MT and LT ventilated applications with twin evaporators; normal regulation restarts only when both evaporators have reached defrost termination temperature
XR70CX  Controller for MT and LT ventilated applications, with auxiliary relay and with dual humidity function on demand, this allows the user to activate or deactivate ventilation directly through keys, in order to regulate the humidity depending on the kind of product (ideal for pastry applications)
XR71CX Controller for MT and LT ventilated applications with anti-sweat heater management; created for applications that utilize heating elements such as anti-mist or anti-freeze heaters on doors (heater elements can be actived by pushing a key or through a dedicated probe)
XR72CX  Controller for MT and LT ventilated applications with dual compressor management
XR75CX Controller for MT and LT ventilated applications with auxiliary relay, dual humidity function and RS485
XR77CX Controller for MT and LT ventilated applications with Real time clock with RS485

 
 
   
HOW TO ORDER
PRIME CX
X R - - C X - A B C D E
 
A B C D E
Power Supply Inputs - Buzzer X-REP
(excludes TTL output)
RS485  output -  Measurement       unit RTC - Compressor  output Connection
0 = 12Vac/dc P = PTC 0 No No No C °C No 0 8A Screw
1 = 12Vac/dc N = NTC 1 Yes No No F °F No 1 20A Screw
2 = 24Vdc S =Pt1000
  only for XR35/75CX
2 No Yes No H
 
°C 
heating only for   XR10CX
No 3 16A Screw
3 = 9 ÷40Vdc 3 Yes Yes No 6 8A Faston
4 = 110Vac -
-
-
-
4 No No Yes L °F 
heating only for   XR10CX
No 7 20A Faston
5 = 230Vac 5 Yes No Yes 8 16A Faston
-
-
6 No Yes Yes I °C Yes -
-
-
-
-
-
7 Yes Yes Yes M °F Yes
 


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now