• Xr160c-0n0c1 Xr570c-0s0c1 Dixell Network Air-Cooled Type Three-Output Thermostat Temperature Controller
  • Xr160c-0n0c1 Xr570c-0s0c1 Dixell Network Air-Cooled Type Three-Output Thermostat Temperature Controller

Xr160c-0n0c1 Xr570c-0s0c1 Dixell Network Air-Cooled Type Three-Output Thermostat Temperature Controller

Customized: Non-Customized
Certification: CE
Brand: Dixell
Display Type: LED
Usage: Refrigerator
Control Type: Digital
Customization:
Diamond Member Since 2011

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company, Other

Basic Info.

Model NO.
Xr160c-0N0C1
Type
Temperature Controller
Material
Plastic
Transport Package
Carton Box
Specification
CE SGS
Trademark
Dixell
Origin
Italy
HS Code
8414301000
Production Capacity
50000PCS/Year

Product Description

 Dixell Network air-cooled type three-output thermostat  Temperature Controller

product description:

Model:Xr160C-0N0C1 


Shell: ABS sublight flame retardant plastic;

Dimensions: front 32x74 mm;Deep 60 mm

Mounting dimensions: fixed in the open hole for 71x29mm panel;

Overall protection level: IP20;Front panel protection level: IP65;

Connecting terminal: bolt pressure, the wire diameter is less than 2.5mm2

Power supply: 230Vac + 10%, 50/60hz

Power consumption: maximum 3VA;

Display: 3 red digital tubes, 14.2 mm high;Input: no. 3 NTC or PTC input

Digital input: 1 channel passive digital signal input

Output relay: compressor/plus hotline: 20(8)A 250Vac;Defrost output: 8(3)A 250Vac;Fan: 5A 250Vac

Data storage: electrically erasable electronic writing memory (EEPROM).

Control level: 1B;Environmental level: 2;Software level: A;

Maximum insulation voltage: 2500V;Grade of overvoltage: II;

Working temperature: 0 ~ 60 ° C;Storage temperature: - 30 ~ 85 ° C.

Relative humidity: 20~85RH% (unexposed)

Measure and control temperature range: NTC: - 40 ~ 110 ° C;PTC: - 50 ~ 150 ° C

Resolution: 0.1 ° C or 1 ° C;Precision (at the ambient temperature of 25 ° C), plus or minus 1 ° C + 1

 
HOW TO ORDER
PRIME CX
X R - - C X - A B C D E
 
A B C D E
Power Supply Inputs - Buzzer X-REP
(excludes TTL output)
RS485  output -  Measurement       unit RTC - Compressor  output Connection
0 = 12Vac/dc P = PTC 0 No No No C °C No 0 8A Screw
1 = 12Vac/dc N = NTC 1 Yes No No F °F No 1 20A Screw
2 = 24Vdc S =Pt1000
  only for XR35/75CX
2 No Yes No H
 
°C 
heating only for   XR10CX
No 3 16A Screw
3 = 9 ÷40Vdc 3 Yes Yes No 6 8A Faston
4 = 110Vac -
-
-
-
4 No No Yes L °F 
heating only for   XR10CX
No 7 20A Faston
5 = 230Vac 5 Yes No Yes 8 16A Faston
-
-
6 No Yes Yes I °C Yes -
-
-
-
-
-
7 Yes Yes Yes M °F Yes
 


 